Background Image

Sch40 Reducing Male Adapter
MPT x Slip

$0.00 USD

½ x ⅜”L
     

More Details
Part NoSizeCtn QtyCodeList PriceLayer QtyPallet QtyCartons/PalletUPCAUCC
436073436-073½ x ⅜10001/B1$1.284000320003202552813710610025528137103
436074436-074½ x ¾5001/B1$1.282000160003202552871858910025528131682
436101436-101¾ x ½5001/B1$1.182000160003202552871859610025528131767
436102436-102¾ x 15001/B1$1.831250112502252552871860210025528131743
436131436-1311 x ¾5001/B1$3.921250112502252552871861910025528718616
436132436-1321 x 1¼2501/B1$4.26100060002402552871862610025528718623
436133436-1331 x 1½2501/B1$4.8162531251252552878171210025528781719
436168436-1681¼ x 12501/B1$4.81100070002802552871161010025528711617
436169436-1691¼ x 1½2501/B1$4.8162556252252552871863310025528718630
436212436-2121½ x 1¼2501/B1$5.8162556252252552871165810025528711655
436213436-2131½ x 21001/B1$5.8140028002802552871864010025528718647
436251436-2512 x 1½1001/B1$6.6240032003202552871170210025528711709
436252436-2522 x 2½1001/B1$10.3325012501252552871169610025528711693
436253436-2532 x 31001/B1$11.5920010001002552877927610025528779273
436293436-2932½ x 31001/B1$12.4720010001002552871171910025528711716
436341436-3413 x 41001/B1$19.97160640642552871172610025528711723
  • ASTM D-1784 - Rigid Poly (Vinyl Chloride) (PVC) Compounds and Chlorinated Poly Vinyl Chloride (CPVC) Compounds
  • ASTM D-2466 - Socket Type Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 40.
  • ASTM F-1970 - Standard Specification for Special Engineered Fittings, Appurtenances or Valves for use in Poly (Vinyl Chloride)(PVC) or Chlorinated Poly (Vinyl Chloride)(CPVC) systems.
  • MATERIAL - LASCO Schedule 40 Fittings are produced from PVC Type 1, Cell Classification 12454-B. -O-rings are produced from a Buna- N (Nitrile) material
  • LISTINGS - NSF/ANSI Standard 61, Annex G: Drinking Water System Components Weighted average lead content of less than or equal to 0.25% and is in compliance with California's Health & Safety Code Section 116875 (commonly known as AB1953) NSF/ANSI Standard 14: Plastics Piping system components and Related Materials. Includes ANSI Standard 61, Annex G
  • Not to be used in the Hot or Cold water distribution system in a dwelling Maximum Service Temperature 140°F
  • Do not use LASCO fittings for compressed air or gases.
  • Do not test PVC piping systems with compressed air or gases.
  • Do not use fittings with liquids not recommended by LASCO
  • Fitting modification voids the warranty.